Product Technical Spec.
Overall Length:
6.000 inches
Overall Height:
1.739 inches
Body Length:
5.660 inches
Body Height:
1.250 inches
Unthreaded Mounting Hole Diameter:
0.219 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
4.130 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
4.380 inches
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 1st radio interference
Load Impedance Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 2nd radio interference
Power Line Frequency Rating Per Function In Hertz:
420.0 1st radio interference
Power Line Frequency Rating Per Function In Hertz:
420.0 2nd radio interference
Power Line Frequency Rating Per Function In Hertz:
420.0 3rd radio interference
Operating Current Rating Per Function In Amps:
3.0 1st radio interference
Operating Current Rating Per Function In Amps:
3.0 3rd radio interference
Operating Current Rating Per Function In Amps:
3.0 2nd radio interference
Maximum Voltage Drop Per Function:
1.15 volts ac 1st radio interference and 4.0 volts dc 1st radio interference
Maximum Voltage Drop Per Function:
1.15 volts ac 2nd radio interference and 4.0 volts dc 2nd radio interference
Maximum Voltage Drop Per Function:
1.15 volts ac 3rd radio interference and 4.0 volts dc 3rd radio interference
Inclosure Type:
Hermetically sealed
Mounting Facility Type And Quantity:
4 unthreaded hole
Functional Terminal Type And Quantity:
3 wire lead output and 1 connector, receptacle input
Operating Voltage Rating And Type Per Function:
115.0 volts ac 1st radio interference 1st function and 400.0 volts dc 1st radio interference 1st function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 2nd radio interference 2nd function and 400.0 volts dc 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 3rd radio interference 3rd function and 400.0 volts dc 3rd radio interference 3rd function
Style Designator:
Rectangular terminal/terminals on opposite surfaces
Item Name:
Emf Interference Filter
Cross Referenced Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC