Technical Specifications of NSN
Overall Height:
2.670 inches
Body Length:
4.750 inches
Body Height:
2.170 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
4.250 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
3.500 inches
Operating Tempurature Range:
-55.0/+85.0 degrees celsius
Average Life Rating In Hours:
1000.0
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
Source Impedance Rating Per Function:
50.0 ohms 5th radio interference
Source Impedance Rating Per Function:
50.0 ohms 6th radio interference
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 1st radio interference
Load Impedance Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 2nd radio interference
Load Impedance Per Function:
50.0 ohms 6th radio interference
Load Impedance Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 5th radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 4th radio interference
Operating Current Rating Per Function In Amps:
1.5 5th radio interference
Operating Current Rating Per Function In Amps:
1.5 6th radio interference
Operating Current Rating Per Function In Amps:
3.5 1st radio interference
Operating Current Rating Per Function In Amps:
3.5 2nd radio interference
Operating Current Rating Per Function In Amps:
3.5 3rd radio interference
Operating Current Rating Per Function In Amps:
3.5 4th radio interference
Maximum Voltage Drop Per Function:
0.28 volts dc 5th radio interference
Maximum Voltage Drop Per Function:
0.28 volts dc 6th radio interference
Maximum Voltage Drop Per Function:
1.15 volts ac 1st radio interference
Maximum Voltage Drop Per Function:
1.15 volts ac 2nd radio interference
Maximum Voltage Drop Per Function:
1.15 volts ac 4th radio interference
Maximum Voltage Drop Per Function:
1.15 volts ac 3rd radio interference
Input Terminal Manufacturer Code:
96214
Input Terminal Identification:
Ms3122e20-16p
Maximum Tempurature Rise:
25.0 degrees celsius
Mounting Facility Screw Thread Series Designator:
Unc
Mounting Facility Type And Quantity:
8 threaded hole
Operating Voltage Rating And Type Per Function:
28.0 volts dc 5th radio interference 5th function
Operating Voltage Rating And Type Per Function:
28.0 volts dc 6th radio interference 6th function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 1st radio interference 1st function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 3rd radio interference 3rd function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 4th radio interference 4th function
Thread Size:
0.138 inches
Body Surface Treatment:
Tin
Unpackaged Unit Weight:
4.100 pounds
Style Designator:
Rectangular terminal/terminals on one surface
Item Name:
Filter,power Line
Other Related Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC