Detail Specifications
Overall Height:
7.040 inches
Body Length:
3.120 inches
Body Height:
6.187 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
2.440 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
1.250 inches
Operating Tempurature Range:
-55.0/+85.0 degrees celsius
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
Source Impedance Rating Per Function:
50.0 ohms 5th radio interference
Source Impedance Rating Per Function:
50.0 ohms 6th radio interference
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference 1st function
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference 3rd function
Source Impedance Rating Per Function:
50.0 ohms 6th radio interference 6th function
Load Impedance Per Function:
50.0 ohms 1st radio interference
Load Impedance Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 2nd radio interference
Load Impedance Per Function:
50.0 ohms 6th radio interference
Load Impedance Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 5th radio interference
Load Impedance Per Function:
50.0 ohms 2nd radio interference 2nd function
Load Impedance Per Function:
50.0 ohms 6th radio interference 6th function
Load Impedance Per Function:
50.0 ohms 4th radio interference 4th function
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 4th radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference 2nd function
Operating Current Rating Per Function In Amps:
0.0001 3rd radio interference
Operating Current Rating Per Function In Amps:
0.0001 4th radio interference
Operating Current Rating Per Function In Amps:
0.01 5th radio interference
Operating Current Rating Per Function In Amps:
0.01 6th radio interference
Operating Current Rating Per Function In Amps:
10.0 1st radio interference
Operating Current Rating Per Function In Amps:
10.0 2nd radio interference
Operating Current Rating Per Function In Amps:
0.0001 3rd radio interference 3rd function
Operating Current Rating Per Function In Amps:
0.01 5th radio interference 5th function
Operating Current Rating Per Function In Amps:
10.0 1st radio interference 1st function
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 5th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 6th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference 4th function
Principal Circuitry Type Per Function:
Inductance-capacitance 6th radio interference 6th function
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference 2nd function
Input Terminal Manufacturer Code:
77820
Input Terminal Identification:
Pt1h14-12p
Mounting Facility Screw Thread Series Designator:
Unc
Mounting Facility Type And Quantity:
10 threaded hole
Functional Terminal Type And Quantity:
1 connector, receptacle input 1st function
Functional Terminal Type And Quantity:
1 tab, solder lug ground 3rd function
Functional Terminal Type And Quantity:
6 tab, solder lug output 2nd function
Operating Voltage Rating And Type Per Function:
10.0 volts dc 3rd radio interference 3rd function
Operating Voltage Rating And Type Per Function:
10.0 volts dc 4th radio interference 4th function
Operating Voltage Rating And Type Per Function:
120.0 volts ac 1st radio interference 1st function
Operating Voltage Rating And Type Per Function:
120.0 volts ac 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function:
120.0 volts ac 5th radio interference 5th function
Operating Voltage Rating And Type Per Function:
120.0 volts ac 6th radio interference 6th function
Thread Size:
0.138 inches
Style Designator:
Rectangular terminal/terminals on opposite surfaces
Item Name:
Filter,power Line
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC