#17889 Bell Ringing Transformer | Coils And Transformers

17889

Power Transformer

NSN 5950-00-233-7651

DEMIL
Shelf Life
UOM
NIIN
Demil:
NO
Shelf Life:
UOM:
NIIN:
002337651

Detail Specifications

Reliability Indicator:
Not established
Mounting Hole Diameter:
0.119 inches single group and 0.124 inches single group
Frequency Rating:
50.0 kilohertz single component
Input-output Phase Relationship:
Single phase to single phase single component
Body Length:
1.000 inches
Body Outside Diameter:
1.600 inches
Inclosure Type:
Fully enclosed
Mounting Facility Quantity:
1 single group
Mounting Method:
Unthreaded hole single group
Winding Function And Quantity:
1 primary single component and 2 secondary single component
Winding Operating Current:
1.0 amperes dc single component 2nd secondary
Winding Operating Current:
3.5 amperes dc single component 1st secondary
Winding Operating Voltage:
102.00 ac volts single component 2nd secondary
Winding Operating Voltage:
34.00 ac volts single component single primary
Winding Operating Voltage:
63.20 ac volts single component 1st secondary
Terminal Type And Quantity:
9 turret
NSN:
5950-00-233-7651
Item Name:
Transformer,bell Ringing
Cage Code:
07388

Manufacturer Part Numbers

Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC
Part Number:
905258-1
Cage Code:
06481
RNCC:
3
RNVC:
2
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
16T110
Cage Code:
11700
RNCC:
5
RNVC:
2
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
1707
Cage Code:
53854
RNCC:
5
RNVC:
2
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
TE13106
Cage Code:
54401
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
70852
Cage Code:
04386
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
70852
Cage Code:
04386
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
R
MSDS:
SADC:
Part Number:
905258-1
Cage Code:
06481
RNCC:
3
RNVC:
2
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
1707
Cage Code:
53854
RNCC:
5
RNVC:
2
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
16T110
Cage Code:
11700
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
F
MSDS:
SADC:
Part Number:
TE13106
Cage Code:
54401
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
F
MSDS:
SADC:
Part Number:
70852
Cage Code:
04386
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
R
MSDS:
SADC:
Part Number:
905258-1
Cage Code:
06481
RNCC:
3
RNVC:
2
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
1707
Cage Code:
53854
RNCC:
5
RNVC:
2
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
16T110
Cage Code:
11700
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
F
MSDS:
SADC:
Part Number:
TE13106
Cage Code:
54401
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
F
MSDS:
SADC:
Part Number:
70852
Cage Code:
04386
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
R
MSDS:
SADC:
Part Number:
905258-1
Cage Code:
06481
RNCC:
3
RNVC:
2
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
1707
Cage Code:
53854
RNCC:
5
RNVC:
2
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
16T110
Cage Code:
11700
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
F
MSDS:
SADC:
Part Number:
TE13106
Cage Code:
54401
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
F
MSDS:
SADC:
Part Number:
70852
Cage Code:
04386
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
R
MSDS:
SADC:

  We Guarantee with Every Order

  •   100% Genuine Manufacturers Parts
  •   Every Product thoroughly Inspected
  •   Sales Record Retention of 7 years
  •   Fast Delivery
  •   HAZMAT Certified
  •   Global Shipping

Pricing & Availability

Submit this form for current pricing and availability quote on part number 17889 and/or cross reference parts.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:

We do not share or sell your information to anyone.
Privacy | Terms

Catalog Drilldown
--- Electrical And Electronic Equipment Components
------ Coils And Transformers
--------- Filament Transformers
------------ P/N 17889

New Products Recently updated in coils and transformers

  • 292MS749P001 power transformer
    NSN 5950-00-020-9324

    4.540 inches overall length, 2.987 inches overall height, 3.802 inches overall width, open inclosure type, 6 single group mounting facility quantity

  • 292MT749P001 power transformer
    NSN 5950-00-020-9324

    4.540 inches overall length, 2.987 inches overall height, 3.802 inches overall width, open inclosure type, 6 single group mounting facility quantity

  • 9T46Y602 power transformer
    NSN 5950-00-020-9523

    0.410 inches single group mounting slot width, 60.0 hertz single component frequency rating, single phase to single phase single component input-output phase relationship

  • SJ20A power transformer
    NSN 5950-00-020-9320

    1.750 inches single mounting facility single center group center to center distance between mounting facilities parallel to length

  • 292MT748P001 power transformer
    NSN 5950-00-020-9320

    1.750 inches single mounting facility single center group center to center distance between mounting facilities parallel to length

  • 292MS748P001 power transformer
    NSN 5950-00-020-9320

    1.750 inches single mounting facility single center group center to center distance between mounting facilities parallel to length


Best-Selling Products A collection of our most popular products

Last Updated: 12/28/2024