Connector pull test: 80 lbs. per mil-prf-39012; next assembly: 196805-01; cable label: w4; drawing number: 196781; length shall be 74.83 to 75.83 feet of continuous coaxial cable; the vswr will be 1.40: 1, 50 ohm impedance; attenuation: the insertion loss shall be less than 17.0 db, at 18.0 ghz; this procurement control drawing describes the requirement for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment
No other part numbers with same form, fit, and function found.
A definite length of cable, radio frequency having one or both ends processed and/or terminated in fittings which provide for connection to other items. Includes multiple cable assemblies in a common jacket or shield. Excludes items having branches or forks and lead, test. See also cable assembly, radio frequency, branched.
Classification: Other instruments and apparatus, specially designed for telecommunications (for examle, cross-talk meters, gain measuring instruments etc)
NSN 5996-00-960-9494
NSN 6620-00-278-7313
NSN 5895-00-169-7912
NSN 6220-01-621-0857
NSN 5910-01-161-6734
NSN 5985-01-046-9976
NSN 6320-01-185-3857
NSN 5998-00-505-2057
NSN 6610-01-329-2289
NSN 5855-00-631-4565
NSN 5905-01-145-1976
NSN 5910-01-153-7486