Product Features
Ruggedized
Product Technical Spec.
Circuit Current For Which Designed:
Dc
Overall Length:
2.234 inches
Center To Center Distance Between Mounting Facilities Parallel To Length:
4.000 inches
Center To Center Distance Between Mounting Facilities Parallel To Width:
3.531 inches
Overall Height:
4.062 inches
Overall Width:
4.531 inches
Scale Division Quantity:
20 single indicator 3rd range
Scale Division Quantity:
40 single indicator 4th range
Mounting Stud Length:
0.390 inches
Environmental Protection:
Shock resistant and vibration resistant
Furnished Items And Quantity:
Nut 2
Indicator Type:
Dial w/pointer
Installation Design:
Panel
Sensitivity Rating:
1.0 milliamperes
Dial Scale Marking Color:
Black single indicator all ranges
Accuracy In Percent:
-1.0/+1.0 at full scale single indicator all ranges
Accuracy In Percent:
-1.0 to 1.0 at full scale single indicator all ranges
Meter Depth Behind Mounting Flange:
0.797 inches
Meter Body Diameter Behind Mounting Flange:
2.750 inches
Movement Type:
Moving coil, permanent magnet
Background Color:
White single indicator all ranges
Pointer Color:
Red single indicator all ranges
Mounting Facility Type And Quantity:
4 threaded stud
Scale Graduation Type:
Linear single indicator 3rd range
Scale Graduation Type:
Linear single indicator 4th range
Scale Graduation Type:
Nonlinear single indicator 1st range
Scale Graduation Type:
Nonlinear single indicator 2nd range
Measurement Range:
+0.0/+15.0 decibels single indicator 1st range
Measurement Range:
+0.0/+2.0 milliamps single indicator 3rd range
Measurement Range:
+0.0/+4.0 milliamps single indicator 4th range
Measurement Range:
+5.0/+30.0 decibels single indicator 2nd range
Measurement Range:
+0.0 to 15.0 decibels single indicator 1st range
Measurement Range:
+0.0 to 2.0 milliamps single indicator 3rd range
Measurement Range:
+5.0 to 30.0 decibels single indicator 2nd range
Measurement Range:
+0.0 to 4.0 milliamps single indicator 4th range
Mounting Stud Diameter:
0.138 inches
Features Provided:
Zero adjuster
Movement Suspension Method:
Jewel pivot base
Circuit Attachment Method And Quantity:
2 threaded stud
Nuclear Hardness Critical Feature:
Nonhardened
Style Designator:
Rectangular flush mtg
Fsc Application Data:
Test set, elect. Equip.
Item Name:
Meter,electrical Indicating
Cross Referenced Parts
No other part numbers with same form, fit, and function found.
Part Identification
INC
FIIG
Concept No.
App. Key
Cond. Code
Status
Part Materials
Hazardous material, precious metals, criticality, enviroment, and electrostatic discharge indicators
HMIC
PMIC
ESD/EMI
ENAC
MMAC
CRITL
Packaging & Shipping
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
Freight Classification
NMFC
UFC
LTL
LCL
WCC
TCC
SHC
ACC