Part number breakdown: 3422=model number, compression fitting style enhanced performance contacting conductivity sensor w/titanium electrodes; c=1.0 cell constant; 6=extended sensor body w/316 stainless steel over electrode; d=316 stainless steel w/3/4 in. Npt conduit connection
A sensor designed to detect the salt content of water by means of electrodes. the item has a threaded fitting for direct pipe connection. it is electrically connected to a panel, salinity monitoring system, shipboard that may activate a dump valve to discharge poor quality water. for cells without a valve see cell, and valve assembly, salinity detector.
Classification: Parts of machinery and apparatus for filtering or purifying water
NSN 6650-01-357-7229
NSN 5975-00-882-4157
NSN 5945-01-461-2401
NSN 5925-01-200-0691
NSN 5990-00-923-4316
NSN 5920-00-234-9002
NSN 5910-01-346-3007
NSN 6150-01-327-7077
NSN 6135-00-128-1633
NSN 6150-01-368-8146
NSN 6620-01-599-2011
NSN 6620-00-193-0518