Voltage requirements 120 vac, 50/60 hz; input resistance to ground 3 megohms ; resistance exceeding 3 megohms triggers alarm; operating temp range 32 degrees f to 122 degrees f; weight 1 lb; enclosures: aluminum, beige and brown enamel input jack on front panel of monitor; green led glows to show the wrist strap is in proper working order; if led goes out and a red led and audible alarm sound it will alert the operator to check the strap; furnished with mounting bracket for mounting on or below the work surface; dimensions of monitor 4 9/16 wide and 1 15/16 inch high
An item specifically designed to test and/or monitor an electrical circuit and indicate its operating condition by means of a display, such as lamps or light emitting diodes. Examples of conditions being indicated are power on, no power, reversed polarity, open ground, open neutral, alternating current and/or direct current. It may or may not be used to indicate definite power line voltage ratings, such as 110, 220 and 440 volts. It is designed to be inserted in the circuit being tested. For items designed to indicate with out physical contact with the object being tested, see indicator, electrical potential. See also light, test, and voltmeter.
Classification: Parts and accessories of articles of schedule b subheading 9030.39
NSN 5998-00-678-3108
NSN 5999-00-625-2561
NSN 5975-01-098-2957
NSN 6620-00-832-2556
NSN 5998-00-469-9798
NSN 6610-00-091-7347
NSN 7035-01-472-5762
NSN 5990-00-721-6666
NSN 5935-00-410-7256
NSN 5915-00-091-1178
NSN 6240-01-541-7009
NSN 4140-01-269-3304