Qmaterial top half case-black anodized aluminum; header-steel; contacts-solderable tinned steel; actuator rod-beryllium copper; bellows-bronze copper alloy; resistance of each element 425 ohms ; temperature range minus 57 degrees c to plus 85 degrees c; operating life one million cycles; mean time between failures with normal use one thousand hours; mean time between failures continuous use three thousand hours; dimensions 1.660 in length; 0.750 in diameter
An item that translates linear displacements of a gas, liquid, or solids into comparable electrical signals for application to equipment, such as telemetric data transmitting set, indicator, recorder, dual air data sensors, and the like. Item can measure pneumatic pressures from pitot impact, pitot-static, and static pressure ports with sensors and convert the pressures to electrical signals. Does not include mechanical linkage, amplifier, or indicator. Excludes sensitive switches and other items that operate on an on-off principal, synchros, and potentiometric type computer devices. See also transmitter (as modified) and transducer, supersonic test.
NSN 4140-01-029-4211
NSN 6130-00-065-8677
NSN 5999-00-325-4525
NSN 5925-01-294-5707
NSN 5925-00-807-9294
NSN 6145-01-499-6520
NSN 5855-01-483-2774
NSN 6240-00-978-9752
NSN 5920-01-286-6792
NSN 6130-01-458-9631
NSN 6130-01-537-7129
NSN 6645-01-416-6979