Per drawing 1385925 - adjustment shall be made by slotted screw and lockout and be accessible from front panel; pressure change due to supply pressure variation of 0.2 psi for 100 psi change; air consumption shall be less than 0.1 scfm.
A valve designed to automatically maintain within close limits a predetermined outlet pressure which may be adjustable within a specified range regardless of the higher fluctuating or constant inlet pressure. It is designed for use with compressed gas(es) and various liquids and may include gauges. It may be inline or cartridge (manifold) design. Excludes regulator, pressure, medical gas administration apparatus; regulator, oxygen, barometric continuous flow; regulator, oxygen demand; regulator, oxygen diluter demand; and valve(1), fluid pressure regulating, aircraft.
Classification: Regulator valves, self-operating, for controlling variables such as temperature, pressure, flow and liquid level
NSN 6220-00-444-9320
NSN 5910-01-580-0324
NSN 7035-00-371-7749
NSN 6620-01-468-6017
NSN 6620-00-448-4378
NSN 5915-00-100-5239
NSN 5930-01-518-4257
NSN 6135-01-131-9352
NSN 5965-01-352-4906
NSN 6645-00-912-0248
NSN 5960-01-546-2379
NSN 6110-01-607-2155