Accuracy pom 0.5% of true flow; response time for step change in flow rate 2 to 5 milliseconds; workingpressure 250 psig at 250 degrees f rated by clamp type; coil inductance 400 to 605 mh; coil resistance 1150 to 1500 ohms; max temperature limits -100 degrees to 200 degrees f; max air or steam purge veloci type 13 cfm; materials body 316 sst, internal finish 150 grit, rotor 17-4 ph sst/cd4mcu, bearings 316 sst, bushings high performance polymer
NSN 5835-01-085-5487
NSN 5905-00-388-0188
NSN 5999-01-354-1833
NSN 5998-01-174-2174
NSN 5996-01-199-6733
NSN 5960-01-386-5770
NSN 5895-01-180-4221
NSN 6135-00-961-3603
NSN 5895-00-606-8915
NSN 5895-00-270-6595
NSN 6150-01-153-2796
NSN 5998-00-414-7999