Stainless steel shell; output voltage 190 volts peak to peak min; threaded shoulder 1.125 in.Lg, 0.625-18 unf-2a thd
An item that translates linear displacements of a gas, liquid, or solids into comparable electrical signals for application to equipment, such as telemetric data transmitting set, indicator, recorder, dual air data sensors, and the like. Item can measure pneumatic pressures from pitot impact, pitot-static, and static pressure ports with sensors and convert the pressures to electrical signals. Does not include mechanical linkage, amplifier, or indicator. Excludes sensitive switches and other items that operate on an on-off principal, synchros, and potentiometric type computer devices. See also transmitter (as modified) and transducer, supersonic test.
NSN 6240-01-651-2850
NSN 5965-00-185-9687
NSN 5935-01-253-0122
NSN 5990-00-787-7758
NSN 6220-01-586-6322
NSN 6320-00-082-5868
NSN 5999-00-597-5054
NSN 6105-00-966-9393
NSN 6650-01-014-7671
NSN 6320-01-261-5983
NSN 5855-01-273-0927
NSN 6220-01-505-9880