91565433

Oscilloscope

NSN 6625-01-245-8406

DEMIL
Shelf Life
UOM
NIIN
Demil:
NO
Shelf Life:
N/A
UOM:
1 EA
NIIN:
012458406

Product Features

Bdc to 100 mhz bandwidth; integrated counter/timer; 2mv sensitivity; advanced trigger system; 5 ns/div sweep rate; delayed sweep measurements; 10x probe; 9 digit, 7 segment vacuum-fluoresent panel

Technical Specifications of NSN

Overall Depth:
17.000 inches
Overall Height:
8.300 inches
Overall Width:
10.800 inches
Current Type:
Ac
Frequency Rating:
Between 48.0 hertz and 440.0 hertz
Voltage Rating:
Between 100.0 volts and 132.0 volts
Beam Quantity:
2
Accuracy Range In Percent:
-4.0/+4.0
Sweep Circuits:
Included
Generator Driven Feature:
Not included
Sweep Circuit Type:
Horizontal and vertical
Sweep Frequency Range:
+0.0/+100.0 megahertz
Single Trigger Sweep Duration:
Between 50.0 nanoseconds and 5.0 seconds
X-axis Frequency Response Rating:
0.0 megahertz and 2.0 megahertz
Y-axis Frequency Response Rating:
0.0 megahertz and 100.0 megahertz
Amplitude Calibrating Voltage Waveform:
Square wave
Trace Storage Tube:
Included
Part Name Assigned By Controlling Agency:
100 mhz ruggedized oscilloscope
Functional Classification:
Aa-9.3
Functional Description:
A 100 mhz counter/timer/dmm is integrated into the scope's vertical, horizontal and trigger systems; this feature simplifies setups by allowing consolidated set-ups and combinations of measurements; heightens measurement confidence and expands the scopes versatility
NSN:
6625-01-245-8406
Item Name:
Digital Phosphor Oscilloscope
Cage Code:
F6481

Other Related Parts

Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC
Part Number:
2236
Cage Code:
80009
RNCC:
3
RNVC:
2
RNAAC:
SB
Status:
A
MSDS:
SADC:
Part Number:
OS6079
Cage Code:
H0G30
RNCC:
5
RNVC:
2
RNAAC:
ZN
Status:
A
MSDS:
SADC:
Part Number:
1858971
Cage Code:
03956
RNCC:
7
RNVC:
2
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
400-6220
Cage Code:
A486G
RNCC:
6
RNVC:
9
RNAAC:
WF
Status:
A
MSDS:
SADC:
Part Number:
2236
Cage Code:
80009
RNCC:
3
RNVC:
2
RNAAC:
SB
Status:
A
MSDS:
SADC:
Part Number:
1858971
Cage Code:
03956
RNCC:
7
RNVC:
2
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
OS6079
Cage Code:
H0G30
RNCC:
5
RNVC:
2
RNAAC:
ZN
Status:
A
MSDS:
SADC:
Part Number:
400-6220
Cage Code:
A486G
RNCC:
6
RNVC:
9
RNAAC:
WF
Status:
A
MSDS:
SADC:
Part Number:
2236
Cage Code:
80009
RNCC:
3
RNVC:
2
RNAAC:
SB
Status:
A
MSDS:
SADC:
Part Number:
1858971
Cage Code:
03956
RNCC:
7
RNVC:
2
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
OS6079
Cage Code:
H0G30
RNCC:
5
RNVC:
2
RNAAC:
ZN
Status:
A
MSDS:
SADC:
Part Number:
400-6220
Cage Code:
A486G
RNCC:
6
RNVC:
9
RNAAC:
WF
Status:
A
MSDS:
SADC:

Part Identification

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00357
FIIG:
T320-G
Concept No.:
App. Key:
GA
Cond. Code:
1
Status:
A

Part Materials

Hazardous material, precious metals, criticality, enviroment, and electrostatic discharge indicators
HMIC
PMIC
ESD/EMI
ENAC
MMAC
CRITL
HMIC:
P
PMIC:
A
ESD:
A
ESD:
A
MMAC:
RH
CRITL:
X

Packaging & Shipping

Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
20.5 X 20.5 X 12.5
Paclk Weight:
22.3000lbs
Item Weight:
17.8000lbs
Item Dim:
014300630000
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
OPI:
O
SPI No.:
F000004B64
SPI Rev.:
SPC Mkg:
19
LVL_A:
LVL_B:

Freight Classification

NMFC
UFC
LTL
LCL
WCC
TCC
SHC
ACC
NMFC:
061700
UFC:
34580
LTL:
RATING VARIABLE
LCL:
100.0
WCC:
658
TCC:
Z
SHC:
Z
ACC:
Equipment for Aircraft

  We Guarantee with Every Order

  •   100% Genuine Manufacturers Parts
  •   Every Product thoroughly Inspected
  •   Sales Record Retention of 7 years
  •   Fast Delivery
  •   HAZMAT Certified
  •   Global Shipping

Pricing & Availability

Submit this form for current pricing and availability quote on part number 91565433 and/or cross reference parts.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:

We do not share or sell your information to anyone.
Privacy | Terms

Definition Definition of approved item name (AIN): "Digital Phosphor Oscilloscope"

A test instrument which is designed to give visual indications on an lcd display or a cathode ray tube of instantaneous values and variations in electrical voltage. It can also be used to indicate any quantity which can be converted into terms of electrical potential. It may include an integral pulse generator, the output of which can be used to trigger an external component; be triggered by pulses from an external source, or it may utilize an lcd display or a special type of multigun cathode ray tube and circuitry which permits a trace(s) to be sustained and displayed indefinitely, and the trace(s) may be erased when desired. For items which are not separable and operable when detached from equipment of which they are a part (built into operational equipment), see indicator (2) (as modified); monitor (as modified); and recorder (as modified). See also oscillograph.

MOE Major Organizational Entities

Entity
DSOR
User:
DEPARTMENT OF THE AIR FORCE Dept. of the Air Force
DSOR:
FR
User:
FINLAND Finland
DSOR:
User:
BRAZIL Brazil
DSOR:
User:
SPAIN Spain
DSOR:
User:
SINGAPORE Singapore
DSOR:
User:
CANADA Canada
DSOR:
User:
FRANCE France
DSOR:
User:
GERMANY Germany
DSOR:
User:
REPUBLIC OF KOREA Republic of Korea
DSOR:
User:
ITALY Italy
DSOR:
User:
DENMARK Denmark
DSOR:
User:
NORWAY Norway
DSOR:
Import / Export
  • Schedule B: 9030908030
  • SITC: 87479
  • End Use: Measuring, testing, control instruments
  • NAICS: 334515
  • USDA: 1

Classification: Parts and accessories of articles of schedule b subheading 9030.39


Best-Selling Products A collection of our most popular products