Second frequency range 200 hz to 3mhz; weight 3 to 6 lbs. Depending on battery config; staveley conductivity probe; digital conductivity display from 0.9 percent to 110 percent; type 3, navy use only; frequency rating 60.0 khz min, 480 khz max; depth 3.600 inches, height 5.500 inches, length 9.500 inches
No other part numbers with same form, fit, and function found.
A non-destructive electromagnetic device which introduces eddy current in a part(s) to be inspected. Changes in the current flow caused by surface variations in the part are reflected into a nearby coil(s) where they are detected and measured by suitable instrumentation which is provided. See also fluorescent penetrant inspection unit; magnetic inspection unit (as modified); transducer, ultrasonic test; x-ray apparatus, radiographic, industrial.
Classification: Physical analysis instruments and apparatus, except using optical radiations, nesoi
NSN 5950-00-186-9315
NSN 5855-00-925-0114
NSN 5915-00-597-2369
NSN 6685-01-066-7472
NSN 5895-00-497-4903
NSN 5950-00-104-8113
NSN 5935-01-175-3893
NSN 6610-01-551-0774
NSN 6105-01-447-5129
NSN 5925-01-423-7429
NSN 5985-01-008-3937
NSN 5965-00-100-1291