Ea series filters are ul 900 listed class 2; media-non-woven cotton and synthetic blend or moisture-resisant miro-fine lofted glass fiber reinforced with remay backing; panel-top and bottom, 1/16 in thick fiber board; adhesive-hot-melt thermoplastic; operating limits 180f degs., average efficiency range 50-55 per cent tested according to ashrae standard 52.1 methods
A replaceable device designed to remove dust, pollen or other foreign matter from the air passing through it. The removal of particles is accomplished by porous fibrous or shredded material (metallic or nonmetallic) which is loosely woven or matted and confined in a frame or retained between perforated sheets of firmer material. It is designed to fit into air conditioners, ventilation systems, hot air furnaces, and electrical and electronic cabinets or housings. It may have facilities for radio frequency/electromagnetic interference shielding. The filter may be cleaned by the use of compressed air, blown through the filter element, or by using water and a suitable detergent for cleaning purposes which would extend the life of the filter.
Classification: Parts, nesoi, of air conditioning machines
NSN 6105-01-446-0732
NSN 6650-01-044-9860
NSN 5996-01-614-4913
NSN 6650-01-328-8363
NSN 5925-00-597-1558
NSN 7035-01-580-5868
NSN 6130-01-527-4126
NSN 5920-01-630-5502
NSN 4140-01-290-4026
NSN 2925-01-025-0082
NSN 6320-01-209-0952
NSN 5999-01-044-4941