Stroke length: 250.0m, operating conditions: mounting position: any, magnet speed: any, operating temp: -40 - +75c, dew point, humidity: 90% rel humidity, no condensation, electronic ingress protection: ip67 if mating cable connector is correctly fitted, shock test: 100 g (single shock) iec-standard 60068-2-27, vibration test: 10 g/10...2000 hz iec standard 60068-2-6 (resonance frequencies excluded), emc test: the sensor meets the requirements of the ec directives and is marked with ce, material: sensor housing and pistion: aluminum, connection type: 5-pin connector m12 (analog), electric strength: 500 vdc (dc ground to machine ground), polarity protection: up to -30 vdc, overvoltage protection: up to 36 vdc.
No other part numbers with same form, fit, and function found.
An item that translates linear displacements of a gas, liquid, or solids into comparable electrical signals for application to equipment, such as telemetric data transmitting set, indicator, recorder, dual air data sensors, and the like. Item can measure pneumatic pressures from pitot impact, pitot-static, and static pressure ports with sensors and convert the pressures to electrical signals. Does not include mechanical linkage, amplifier, or indicator. Excludes sensitive switches and other items that operate on an on-off principal, synchros, and potentiometric type computer devices. See also transmitter (as modified) and transducer, supersonic test.
NSN 5960-00-833-6042
NSN 5990-00-832-2557
NSN 6240-01-282-0983
NSN 5965-01-382-9081
NSN 5999-01-109-5877
NSN 5965-01-348-8761
NSN 5975-01-471-3828
NSN 5905-01-423-4235
NSN 5925-00-337-8138
NSN 2925-01-562-8051
NSN 5945-01-004-8591
NSN 5910-01-080-0447