8.5000" between elbows; elbows have 0.500 to 0.504"id; each end of exchanger has 0.878"id; has 2hp capacity; used on 120-14 (6fpi) and 136-139(fpi) ; electric & hot gas defrost models; work pressure 450 psi; capci type 2 hp; use w/r-22, r-404a, r502, r507, r-134a; 1/2" od liquid connection; 7/8" od suction connection
No other part numbers with same form, fit, and function found.
An apparatus designed to lower the temperature of the liquid refrigerant and raise the temperature of the suction vapor by permitting the transfer of heat from both through the walls of the separating chambers.
NSN 5925-01-500-4263
NSN 5999-01-351-3770
NSN 6150-01-602-6899
NSN 6240-00-350-9508
NSN 5965-01-025-5129
NSN 6145-00-841-8308
NSN 7035-01-017-2702
NSN 5960-01-032-4229
NSN 5920-00-450-1978
NSN 7035-00-946-2642
NSN 6645-00-066-6868
NSN 6610-00-664-2190