Power supply: 95-240 v ac, 47-64 hz, 100 w; 110 vac ceilometer; measurment range: 12, 500 to 25, 000 ft (selectable); resolution: 12.5 ft; accuracy: +/-20 ft; cloud layers: up to 4, base and depth; measurement cycle: configurable to 30, 60, or 120 second sampling per reporting interval; can be set to 180 sec. When no clouds detected; operating temp: -40?C to +60?C; storage temp; -50?C to +70?C; relative humidity: 0-100%, condensing; laser: lidar: ingaas, pulsed diode; wave length: 905 +/- 10nm; pulse width: 50ns; collector type: si avalanch photodiode, variable gain, temp compensated; optics: side by side
No other part numbers with same form, fit, and function found.
A group of related items which senses and indicates and/or records measurements for determining the height of clouds above the point of projection.
Classification: Parts and accessories for surveying
NSN 4140-01-270-1067
NSN 5925-01-550-9653
NSN 6610-00-336-2404
NSN 6240-01-159-2633
NSN 6685-01-564-4896
NSN 5950-01-160-9439
NSN 5915-01-242-9546
NSN 7035-00-585-2113
NSN 6150-01-010-1877
NSN 5915-00-811-5443
NSN 5930-01-412-8416
NSN 6320-01-642-2615