Fmeasuring ranges: oxygen 0 to 30% by volumbe and combustibles 0 to 100% lower explosive limit (lel); alarms are aduble and visual; approvals from ul and csa; weight 18 ounces; 2 different power sources depending on option chosen: option 1810-1527 power source rechargeable n ickel cadmium battery pack operating time 10 hours; option 1810-1550 power source 4 aaa alkaline batteries operating time 8 hours; dual sensors; accuracy 0.5 to 1%
An instrument which detects electrically and indicates visually concentrations of combustible gas and/or vapors in air. It is designed to be carried in the hand or attached to the person. May include features such as audible, visible,vibration or warning alarms, and recording systems such as data logging.
Classification: Chemical analysis instruments and apparatus, nesoi
NSN 6620-01-388-1430
NSN 5965-01-120-9618
NSN 5920-01-159-5101
NSN 5905-01-623-2417
NSN 5930-01-063-5914
NSN 6145-01-214-5374
NSN 6135-01-322-4655
NSN 6110-01-273-3136
NSN 5999-01-289-4043
NSN 5910-01-477-1608
NSN 6320-00-456-2092
NSN 5925-00-313-6049