Detail Specifications
Terminal Material:
Copper alloy
Terminal Surface Treatment:
Solder dip
Overall Length:
1.055 inches
Terminal Length:
0.740 inches
Body Length:
0.315 inches
Overall Diameter:
0.335 inches
Continuous Current Rating In Amps:
0.125
Terminal Diameter:
0.024 inches
Center To Center Distance Between Mounting Facilities Parallel To Diameter:
0.200 inches
Fragility Factor:
Moderately rugged
Maximum Voltage Rating In Volts:
250.0 ac and 250.0 dc
Circuit Over-current Interruption Type:
Time delay
Interruption Indicator Method:
Opaque body
End Application:
6625-01-196-8335 test set, electr
Features Provided:
Nonrenewable fusible element
Circuit Over-current Interruption Delay Time In Seconds:
12.0 200 pct of current rating
Short-circuit/interrupt Current Rating In Amps:
200000.0
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC