Detail Specifications
Terminal Material:
Copper or brass
Terminal Surface Treatment:
Nickel
Overall Length:
1.250 inches
Overall Diameter:
0.281 inches
Continuous Current Rating In Amps:
5.000
Maximum Voltage Rating In Volts:
32.0 dc
Circuit Over-current Interruption Type:
Time delay
Interruption Indicator Method:
Opaque body
Features Provided:
Nonrenewable fusible element
Circuit Over-current Interruption Delay Time In Seconds:
25.0 200 pct of current rating and 8.0 300 pct of current rating and 3.0 500 pct of current rating
Short-circuit/interrupt Current Rating In Amps:
200.0
Special Test Features:
Fuse has been tested in a 125v AC envoronment and found satisfactory for use in c-130 125 volt application; for determination of applicability in any other system
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC