Detail Specifications
Terminal Material:
Copper or brass
Terminal Surface Treatment:
Silver plated
Overall Length:
1.250 inches
Overall Diameter:
0.250 inches
Continuous Current Rating In Amps:
2.000
Maximum Voltage Rating In Volts:
250.0 ac
Circuit Over-current Interruption Type:
Normal instantaneous
Interruption Indicator Method:
Visible element
Features Provided:
Nonrenewable fusible element
Short-circuit/interrupt Current Rating In Amps:
35.0
Test Data Document:
81205-bacf30a4-20 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Manufacturer Part Numbers
No other part numbers with same form, fit, and function found.