Product Technical Spec.
Terminal Material:
Brass or copper or copper alloy
Overall Length:
Between 7.030 inches and 7.210 inches
Center To Center Distance Between Mounting Facilities Parallel To Length:
Between 5.190 inches and 5.310 inches
Mounting Slot Width:
Between 0.401 inches and 0.411 inches
Overall Diameter:
2.120 inches
Case Material:
Ceramic or fiber
Continuous Current Rating In Amps:
225.000
Terminal Width:
Between 1.590 inches and 1.660 inches
Terminal Thickness:
Between 0.247 inches and 0.253 inches
Maximum Voltage Rating In Volts:
600.0 ac and 600.0 dc
Circuit Over-current Interruption Type:
Time delay
Interruption Indicator Method:
Opaque body
Features Provided:
Nonrenewable fusible element
Circuit Over-current Interruption Delay Time In Seconds:
600.0 200 pct of current rating
Short-circuit/interrupt Current Rating In Amps:
200000.0
Test Data Document:
81348-w-f-1814 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Specification Data:
81348-w-f-1814/9 government specification
Item Name:
Time Delayed Fuse
Cross Referenced Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC