Part name assigned by controlling agency - spikeguard suppressor; rated at 20000.0 peak amperes for 10.0 microseconds; breakdown voltage 1100.0 volts; gas discharge clamping device; clamps transients having rise times of 1.0 kilovolt per nanosecond; clamping begins in 2.0 to 6.0 nanoseconds depending upon risetime; limits transient energy to lessthan 2 millijoules; one male and one female type n coaxial connector; insertion loss is less t han 0.1 decibel over frequency range of 1.5 to 800.0 megahertz; frequency range 1.5 megahertz to 1.0 gigahertz
No other part numbers with same form, fit, and function found.
NSN 6610-01-152-2821
NSN 6150-01-380-9723
NSN 5950-01-014-6610
NSN 5990-00-193-3028
NSN 4140-01-112-8550
NSN 6145-01-540-9957
NSN 5905-01-172-8421
NSN 5855-01-278-8922
NSN 6685-01-483-8542
NSN 5930-01-109-8477
NSN 5975-01-367-1859
NSN 5835-01-043-1576