Technical Specifications of NSN
Overall Length:
4.343 inches
Center To Center Distance Between Mounting Facilities Parallel To Length:
3.687 inches single mounting facility
Center To Center Distance Between Mounting Facilities Parallel To Width:
3.500 inches single mounting facility
Overall Height:
3.956 inches
Overall Width:
4.156 inches
Unthreaded Mounting Hole Diameter:
0.218 inches single mounting facility
Mounting Facility Type And Quantity:
4 unthreaded hole single mounting facility
Mounting Facility Pattern:
Rectangular single mounting facility
Nonpile-up Main Contact Arrangement:
3 pole, single throw, normally open, momentary action
Nonpile-up Auxiliary Contact Arrangement:
2 pole, single throw, normally open, double make, momentary action
Auxiliary Contact Maximum Voltage Rating In Volts:
115.0 ac and 28.0 dc
Operating Voltage Rating And Type At Specificationified Temp:
115.0 volts ac 25 degrees celsius single winding
Main Contact Load Current Rating At Maximum Rated Voltage:
100.0 amperes ac motor load and 100.0 amperes dc motor load
Main Contact Load Current Rating At Maximum Rated Voltage:
150.0 amperes ac resistive load and 150.0 amperes dc resistive load
Main Contact Maximum Voltage Rating In Volts:
115.0 ac and 28.0 dc
Auxiliary Contact Load Current Rating At Maximum Rated Voltage:
10.0 amperes ac resistive load and 10.0 amperes dc resistive load
Auxiliary Contact Load Current Rating At Maximum Rated Voltage:
3.0 amperes ac lamp load and 3.0 amperes dc lamp load
Auxiliary Contact Load Current Rating At Maximum Rated Voltage:
5.0 amperes ac motor load and 5.0 amperes dc motor load
Test Data Document:
81349-mil-r-6106 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Terminal Type And Quantity:
12 threaded stud all functions
Specification Data:
96906-ms27715 government standard
Item Name:
Latching Relay
Other Related Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS