Hermetically sealed; total submersibility; insulation resistance 1000.0 megohms min. At 500 vdc; breakdown voltage 500.0 volts rms 60.0 hertz between all mutually insulated points; temp. Range minus 55.0 to plus 71.0 deg. C; rated life 100000 operations min. At max. Rated load; terminals 0.030 in. Dia. Located on 0.200 in. Grid pattern; configuration 2 form c, double pole double throw; contact resistance 50.0 milliohms max. Initial measured at max. Rated load; sensitivity of 350.0 milliwatts at plus 25.0 deg. C; power 660.0 milliwatts at plus 25.0 deg. C; 24 volt coil; weight is 0.035 ounces
No other part numbers with same form, fit, and function found.
1.780 inches overall length, 1.062 inches single mounting facility center to center distance between mounting facilities parallel to length
1.780 inches overall length, 1.062 inches single mounting facility center to center distance between mounting facilities parallel to length
Riveted on mounting configuration
2b single mounting facility thread class, 1.680 inches overall length, 1.680 inches overall height, 1.000 inches overall width
Steel case material, nickel case surface treated, explosion proof environmental protection, intermittent duty type, 30.0 dc voltage rating in volts
2a single mounting facility thread class, 4.250 inches overall length, 2.625 inches single mounting facility center to center distance between mounting facilities parallel to length
NSN 5905-00-629-0111
NSN 6685-00-390-8687
NSN 5965-00-150-1144
NSN 6150-01-503-0795
NSN 5960-00-402-7564
NSN 7035-00-312-3055
NSN 5915-00-439-5891
NSN 5910-01-147-5351
NSN 4140-01-397-6940
NSN 5965-01-612-3799
NSN 6650-00-139-8345
NSN 6620-01-621-0719
Last Updated: 11/22/2024