Detail Specifications
Overall Length:
2.600 inches
Center To Center Distance Between Mounting Facilities Parallel To Length:
2.000 inches single mounting facility
Center To Center Distance Between Mounting Facilities Parallel To Width:
2.000 inches single mounting facility
Overall Height:
2.500 inches
Overall Width:
2.440 inches
Environmental Protection:
Hermetic
Unthreaded Mounting Hole Diameter:
0.171 inches single mounting facility
Fragility Factor:
Moderately rugged
Winding Dc Resistance Rating:
200.0 ohms single winding
Arc Quenching Method:
Air
Mounting Facility Type And Quantity:
4 unthreaded hole single mounting facility
Storage Type:
General purpose warehouse
Mounting Facility Pattern:
Rectangular single mounting facility
Nonpile-up Main Contact Arrangement:
3 pole, single throw, normally open, momentary action
Time Delay:
0.025 seconds fixed release time
Time Delay:
0.05 seconds fixed operate time
Nonpile-up Auxiliary Contact Arrangement:
1 pole, single throw, normally open, momentary action
Auxiliary Contact Maximum Voltage Rating In Volts:
115.0 ac and 28.0 dc
Operating Voltage Rating And Type At Specificationified Temp:
28.0 volts dc 25 degrees celsius single winding
Main Contact Load Current Rating At Maximum Rated Voltage:
55.0 amperes ac inductive load and 15.0 amperes dc inductive load
Main Contact Load Current Rating At Maximum Rated Voltage:
55.0 amperes ac lamp load and 10.0 amperes dc lamp load
Main Contact Load Current Rating At Maximum Rated Voltage:
55.0 amperes ac motor load and 15.0 amperes dc motor load
Main Contact Load Current Rating At Maximum Rated Voltage:
55.0 amperes ac resistive load and 25.0 amperes dc resistive load
Main Contact Maximum Voltage Rating In Volts:
115.0 ac and 28.0 dc
Auxiliary Contact Load Current Rating At Maximum Rated Voltage:
1.0 amperes ac lamp load and 1.0 amperes dc lamp load
Auxiliary Contact Load Current Rating At Maximum Rated Voltage:
3.0 amperes ac inductive load and 3.0 amperes dc inductive load
Auxiliary Contact Load Current Rating At Maximum Rated Voltage:
3.0 amperes ac resistive load and 3.0 amperes dc resistive load
Test Data Document:
53711-6022170 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Terminal Type And Quantity:
10 threaded stud all functions
Item Name:
Time Delay Relay
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS