Overall Length:
3.000 inches
Center To Center Distance Between Mounting Facilities Parallel To Length:
2.625 inches first mounting facility
Center To Center Distance Between Mounting Facilities Parallel To Length:
2.625 inches second mounting facility
Center To Center Distance Between Mounting Facilities Parallel To Width:
1.250 inches first mounting facility
Center To Center Distance Between Mounting Facilities Parallel To Width:
1.250 inches second mounting facility
Overall Height:
2.700 inches
Overall Width:
2.300 inches
Environmental Protection:
Hermetic
Unthreaded Mounting Hole Diameter:
0.173 inches first mounting facility
Unthreaded Mounting Hole Diameter:
0.173 inches second mounting facility
Fragility Factor:
Moderately rugged
Purpose For Which Designed:
General
Arc Quenching Method:
Air
Mounting Facility Type And Quantity:
6 unthreaded hole first mounting facility
Mounting Facility Type And Quantity:
6 unthreaded hole second mounting facility
Storage Type:
General purpose warehouse
Cubic Measure:
18.630 cubic inches
Mounting Facility Pattern:
Rectangular first mounting facility
Mounting Facility Pattern:
Rectangular second mounting facility
Nonpile-up Main Contact Arrangement:
4 pole, double throw, one position momentary
Operating Current Rating And Type:
500.0 milliamperes dc single winding
Time Delay:
0.02 seconds fixed release time
Time Delay:
0.025 seconds fixed operate time
Operating Voltage Rating And Type At Specificationified Temp:
28.0 volts dc 25 degrees celsius single winding
Main Contact Load Current Rating At Maximum Rated Voltage:
3.0 amperes ac lamp load and 3.0 amperes dc lamp load
Main Contact Load Current Rating At Maximum Rated Voltage:
6.0 amperes ac motor load and 6.0 amperes dc motor load
Main Contact Load Current Rating At Maximum Rated Voltage:
10.0 amperes ac inductive load and 10.0 amperes dc inductive load
Main Contact Load Current Rating At Maximum Rated Voltage:
15.0 amperes ac resistive load and 10.0 amperes dc resistive load
Main Contact Maximum Voltage Rating In Volts:
115.0 ac and 28.0 dc
Test Data Document:
81349-mil-r-6106 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Terminal Type And Quantity:
14 screw all functions
Specification Data:
96906-ms24568 government standard
Item Name:
Current Control Relay
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC