Detail Specifications
Overall Length:
Between 3.714 inches and 3.734 inches
Center To Center Distance Between Mounting Facilities Parallel To Length:
3.250 inches single mounting facility
Center To Center Distance Between Mounting Facilities Parallel To Width:
2.687 inches single mounting facility
Overall Height:
Between 2.347 inches and 2.941 inches
Overall Width:
Between 3.285 inches and 3.305 inches
Environmental Protection:
Hermetic
Unthreaded Mounting Hole Diameter:
0.218 inches single mounting facility
Fragility Factor:
Moderately rugged
End Application:
Bsy1 fy88
Purpose For Which Designed:
General
Winding Dc Resistance Rating:
51.0 ohms single winding
Arc Quenching Method:
Air
Mounting Facility Type And Quantity:
4 unthreaded hole single mounting facility
Storage Type:
General purpose warehouse
Features Provided:
Polarized
Cubic Measure:
36.294 cubic inches
Mounting Facility Pattern:
Rectangular single mounting facility
Nonpile-up Main Contact Arrangement:
3 pole, single throw, normally open, double make, momentary action
Operating Current Rating And Type:
600.0 milliamperes dc single winding
Time Delay:
0.01 seconds fixed release time
Time Delay:
0.025 seconds fixed operate time
Nonpile-up Auxiliary Contact Arrangement:
1 pole, single throw, normally open, double make, momentary action and 1 pole, single throw, normally closed, double break, momentary action
Auxiliary Contact Maximum Voltage Rating In Volts:
115.0 ac and 28.0 dc
Operating Voltage Rating And Type At Specificationified Temp:
28.0 volts dc 25 degrees celsius single winding
Main Contact Load Current Rating At Maximum Rated Voltage:
50.0 amperes ac inductive load and 50.0 amperes dc inductive load
Main Contact Load Current Rating At Maximum Rated Voltage:
50.0 amperes ac motor load and 50.0 amperes dc motor load
Main Contact Load Current Rating At Maximum Rated Voltage:
50.0 amperes ac resistive load and 50.0 amperes dc resistive load
Main Contact Load Current Rating At Maximum Rated Voltage:
1.0 amperes ac lamp load and 1.0 amperes dc lamp load
Main Contact Maximum Voltage Rating In Volts:
115.0 ac and 28.0 dc
Auxiliary Contact Load Current Rating At Maximum Rated Voltage:
1.0 probe ac lamp load and 1.0 probe dc lamp load
Auxiliary Contact Load Current Rating At Maximum Rated Voltage:
5.0 probe ac resistive load and 5.0 probe dc resistive load
Auxiliary Contact Load Current Rating At Maximum Rated Voltage:
5.0 probe ac inductive load and 5.0 probe dc inductive load
Test Data Document:
81349-mil-r-6106 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Terminal Type And Quantity:
12 tab, solder lug all functions
Specification Data:
96906-ms27222 government standard
Item Name:
Solenoid Relay
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC
Part Number:
MIL-PRF-6106