Technical Specifications of NSN
Overall Length:
Between 4.660 inches and 4.720 inches
Center To Center Distance Between Mounting Facilities Parallel To Length:
3.927 inches single mounting facility and 3.947 inches single mounting facility
Center To Center Distance Between Mounting Facilities Parallel To Width:
2.833 inches single mounting facility and 2.853 inches single mounting facility
Overall Height:
Between 4.220 inches and 4.280 inches
Overall Width:
Between 3.560 inches and 3.620 inches
Environmental Protection:
Hermetic
Unthreaded Mounting Hole Diameter:
0.208 inches single mounting facility and 0.228 inches single mounting facility
Fragility Factor:
Moderately rugged
Purpose For Which Designed:
General
Arc Quenching Method:
Air
Mounting Facility Type And Quantity:
4 unthreaded hole single mounting facility
Storage Type:
General purpose warehouse
Cubic Measure:
73.130 cubic inches
Mounting Facility Pattern:
Rectangular single mounting facility
Nonpile-up Main Contact Arrangement:
3 pole, double throw, one position momentary
Nonpile-up Auxiliary Contact Arrangement:
6 pole, double throw, one position momentary
Auxiliary Contact Maximum Voltage Rating In Volts:
115.0 ac and 28.0 dc
Operating Voltage Rating And Type At Specificationified Temp:
30.0 volts dc 25 degrees celsius single winding
Main Contact Load Current Rating At Maximum Rated Voltage:
80.0 amperes ac motor load
Main Contact Load Current Rating At Maximum Rated Voltage:
120.0 amperes ac inductive load
Main Contact Load Current Rating At Maximum Rated Voltage:
120.0 amperes ac resistive load
Main Contact Maximum Voltage Rating In Volts:
200.0 ac
Auxiliary Contact Load Current Rating At Maximum Rated Voltage:
1.0 amperes ac lamp load and 1.0 amperes dc lamp load
Auxiliary Contact Load Current Rating At Maximum Rated Voltage:
5.0 amperes ac inductive load and 5.0 amperes dc inductive load
Auxiliary Contact Load Current Rating At Maximum Rated Voltage:
5.0 amperes ac resistive load and 5.0 amperes dc resistive load
Test Data Document:
81349-mil-r-6106 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Terminal Type And Quantity:
1 connector, receptacle energizing element
Terminal Type And Quantity:
9 threaded stud contacts
Specification Data:
81349-mil-r-6106/46 government specification
Item Name:
Latching Relay
Other Related Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC