Detail Specifications
Overall Length:
3.700 inches
Center To Center Distance Between Mounting Facilities Parallel To Length:
3.250 inches single mounting facility
Center To Center Distance Between Mounting Facilities Parallel To Width:
2.667 inches single mounting facility
Overall Height:
3.200 inches
Overall Width:
3.305 inches
Environmental Protection:
Hermetic
Unthreaded Mounting Hole Diameter:
0.218 inches single mounting facility
Fragility Factor:
Moderately rugged
Purpose For Which Designed:
General
Winding Dc Resistance Rating:
52.0 ohms single winding
Arc Quenching Method:
Air
Mounting Facility Type And Quantity:
4 unthreaded hole single mounting facility
Storage Type:
General purpose warehouse
Cubic Measure:
39.131 cubic inches
Mounting Facility Pattern:
Rectangular single mounting facility
Nonpile-up Main Contact Arrangement:
3 pole, single throw, normally open, double make, momentary action
Time Delay:
0.01 seconds fixed release time
Time Delay:
0.025 seconds fixed operate time
Nonpile-up Auxiliary Contact Arrangement:
1 pole, single throw, normally closed, double break, momentary action and 1 pole, single throw, normally open, double make, momentary action
Auxiliary Contact Maximum Voltage Rating In Volts:
115.0 ac and 28.0 dc
Operating Voltage Rating And Type At Specificationified Temp:
28.0 volts dc 25 degrees celsius single winding
Main Contact Load Current Rating At Maximum Rated Voltage:
50.0 amperes ac inductive load and 50.0 amperes dc inductive load
Main Contact Load Current Rating At Maximum Rated Voltage:
50.0 amperes ac motor load and 50.0 amperes dc motor load
Main Contact Load Current Rating At Maximum Rated Voltage:
50.0 amperes ac resistive load and 50.0 amperes dc resistive load
Main Contact Maximum Voltage Rating In Volts:
115.0 ac and 28.0 dc
Auxiliary Contact Load Current Rating At Maximum Rated Voltage:
5.0 amperes ac inductive load and 5.0 amperes dc inductive load
Auxiliary Contact Load Current Rating At Maximum Rated Voltage:
5.0 amperes ac resistive load and 5.0 amperes dc resistive load
Auxiliary Contact Load Current Rating At Maximum Rated Voltage:
750.0 milliamperes ac lamp load and 750.0 milliamperes dc lamp load
Test Data Document:
81349-mil-r-6106 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Terminal Type And Quantity:
12 threaded stud all functions
Specification Data:
96906-ms24376 government standard
Item Name:
Antenna Switching Relay
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC