Detail Specifications
Body Style:
Cylindrical servo mounted
Reliability Indicator:
Not established
Pilot Diameter:
1.0000 inches
Pilot Length:
0.0670 inches
Undercut Diameter:
1.310 inches
Undercut Width:
0.0570 inches
Body Diameter:
1.442 inches
Shaft Diameter:
0.187 inches
Shaft Length:
0.760 inches
Body Length:
3.332 inches
Mounting Lip Diameter:
1.4450 inches
Mounting Lip Depth:
0.0670 inches
Switch Voltage Rating In Volts:
30.0
Actuator Type:
Single shaft
Effective Electrical Rotation In Deg Angular Rotation:
352.0
Switch Operating Position:
Start of rotation
Switch Contact Arrangement:
Single pole, single throw, normally open, both positions maintained
Terminal Location:
Radially positioned over less than half the circumference
Mounting Method:
Clamp ring
Features Provided:
Switch
Electrical Resistance Per Section:
10.0 percent, rated amperes c and better industrial clears
Electrical Resistance Per Section:
2.5 percent, rated amperes c and better v.G. Stepping
Electrical Resistance Per Section:
5.0 percent, rated amperes c and better finish
Electrical Resistance Per Section:
6.5 percent, rated amperes c drop siding
Electrical Resistance Per Section:
5.0 kilohms 1st section
Electrical Resistance Per Section:
6.5 kilohms 5th section
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation:
176.0 5th section
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation:
180.0 3rd section
Rotary Actuator Travel In Angular Deg:
360.0
Function Conformity Tolerance Per Section:
-0.50/+0.50 1st section
Function Conformity Tolerance Per Section:
-0.50/+0.50 2nd section
Function Conformity Tolerance Per Section:
-1.00/+1.00 4th section
Function Conformity Tolerance Per Section:
-1.00/+1.00 5th section
Function Conformity Tolerance Per Section:
-0.75/+0.75 3rd section
Function Conformity Tolerance Per Section:
-0.50 to 0.50 1st section
Function Conformity Tolerance Per Section:
-0.75 to 0.75 3rd section
Function Conformity Tolerance Per Section:
-1.00 to 1.00 5th section
Power Dissipation Rating Per Section In Watts:
2.0 free air all sections
Function Conformity Per Section:
All sections absolute conformity
Fixed Tap Quantity Per Section:
1 3rd section
Fixed Tap Quantity Per Section:
1 5th section
Tap Location Tolerance Per Section:
-0.025/+0.025 degrees angular rotation all sections
Resistance Tolerance Per Section In Percent:
-1.0/+1.0 3rd section
Resistance Tolerance Per Section In Percent:
-2.0/+2.0 4th section
Resistance Tolerance Per Section In Percent:
-2.0/+2.0 1st section
Resistance Tolerance Per Section In Percent:
-2.0/+2.0 2nd section
Resistance Tolerance Per Section In Percent:
-3.0/+3.0 5th section
Resistance Tolerance Per Section In Percent:
-2.0 to 2.0 1st section
Resistance Tolerance Per Section In Percent:
-2.0 to 2.0 4th section
Actuator Travel Control Feature:
Continuous motion
Function Characteristic Per Section:
All sections table
Switch Current Type And Rating In Amps:
0.003 dc
Terminal Type And Quantity:
19 turret
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC