Detail Specifications
Body Style:
Cylindrical servo mounted
Reliability Indicator:
Not established
Pilot Diameter:
Between 0.7490 inches and 0.7500 inches
Pilot Length:
Between 0.0570 inches and 0.0670 inches
Undercut Diameter:
Between 0.749 inches and 0.750 inches
Undercut Width:
0.0570 inches
Body Diameter:
0.875 inches
Shaft Diameter:
0.1248 inches
Shaft Length:
0.375 inches
Body Length:
1.610 inches
Mounting Lip Diameter:
Between 0.8700 inches and 0.8750 inches
Mounting Lip Depth:
Between 0.0570 inches and 0.0670 inches
Shaft Bearing Type:
Bearing
Actuator Type:
Single shaft
Effective Electrical Rotation In Deg Angular Rotation:
3418.4
Maximum Starting Torque:
0.60 inch-ounces
Maximum Running Torque:
0.60 inch-ounces
Shaft End Play:
0.005 inches
Shaft Runout:
0.001 inches
Lateral Runout:
0.003 inches
Pilot Diameter Runout:
0.0015 inches
Shaft Radial Play:
0.002 inches
Terminal Location:
Radially positioned over more than half the circumference
Mounting Method:
Clamp ring
Features Provided:
Nonmetallic shaft
Electrical Resistance Per Section:
30.0 kilohms single section
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation:
1259.4 single section
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation:
1529.3 single section
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation:
1799.1 single section
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation:
2069.0 single section
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation:
2238.9 single section
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation:
2608.8 single section
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation:
2878.6 single section
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation:
3148.5 single section
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation:
3418.4 single section
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation:
449.8 single section
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation:
717.7 single section
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation:
989.5 single section
Rotary Actuator Travel In Angular Deg:
3500.0
Function Conformity Tolerance Per Section:
-0.10/+0.10 single section
Ambient Tempurature In Deg Celsius Per Section At Zero Percent Rated Power:
85.0 single section
Power Dissipation Rating Per Section In Watts:
0.5 free air single section
Function Conformity Per Section:
Single section independent linearity
Fixed Tap Quantity Per Section:
12 single section
Tap Location Tolerance Per Section:
-1.7/+1.7 ohms all sections
Resistance Tolerance Per Section In Percent:
-5.0/+5.0 single section
Actuator Travel Control Feature:
Stops
Function Characteristic Per Section:
Single section linear
Ambient Tempurature In Deg Celsius Per Section At Full Rated Power:
105.0 single section
Terminal Type And Quantity:
15 turret
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC