Product Technical Spec.
Reliability Indicator:
Not established
Terminal Length:
1.250 inches
Body Length:
0.410 inches
Body Outside Diameter:
0.140 inches
Terminal Diameter:
0.025 inches
Maximum Power Dissipation Rating:
500.00 milliwatts
Ambient Tempurature At Full Rated Power:
25.0 degrees celsius
Maximum Operating Temp:
125.0 degrees celsius
Thermal Time Constant In Seconds:
60.0
Power Dissipation Constant In Milliwatts Per Deg Celsius:
5.0
Tempurature Points For Resistance Readings At Zero Power:
-15.0 degrees celsius 2nd resistance-temperature point
Tempurature Points For Resistance Readings At Zero Power:
-55.0 degrees celsius 1st resistance-temperature point
Tempurature Points For Resistance Readings At Zero Power:
100.0 degrees celsius 5th resistance-temperature point
Tempurature Points For Resistance Readings At Zero Power:
125.0 degrees celsius 6th resistance-temperature point
Tempurature Points For Resistance Readings At Zero Power:
50.0 degrees celsius 3rd resistance-temperature point
Tempurature Points For Resistance Readings At Zero Power:
75.0 degrees celsius 4th resistance-temperature point
Zero Power Resistance At Specificationified Temp:
4.1 kilohms 3rd resistance-temperature point
Zero Power Resistance At Specificationified Temp:
4.8 kilohms 4th resistance-temperature point
Zero Power Resistance At Specificationified Temp:
5.5 kilohms 5th resistance-temperature point
Zero Power Resistance At Specificationified Temp:
6.5 kilohms 6th resistance-temperature point
Zero Power Resistance At Specificationified Temp:
1.7 kilohms 1st resistance-temperature point
Zero Power Resistance At Specificationified Temp:
2.4 kilohms 2nd resistance-temperature point
Resistance Tolerance At A Specificationified Tempurature In Percent:
-12.0/+12.0 3rd resistance-temperature point
Resistance Tolerance At A Specificationified Tempurature In Percent:
-14.0 to 14.0 2nd resistance-temperature point
Resistance Tolerance At A Specificationified Tempurature In Percent:
-14.0 to 14.0 4th resistance-temperature point
Resistance Tolerance At A Specificationified Tempurature In Percent:
-17.0/+17.0 5th resistance-temperature point
Resistance Tolerance At A Specificationified Tempurature In Percent:
-20.0 to 20.0 6th resistance-temperature point
Resistance Tolerance At A Specificationified Tempurature In Percent:
-20.0/+20.0 1st resistance-temperature point
Inclosure Type:
Encapsulated
Zero Power Resistance:
3.300 kilohms
Zero Power Resistance Tolerance In Percent At Reference Temp:
-10.0/+10.0
Test Data Document:
81349-milt23648 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Terminal Type And Quantity:
2 wire lead
Cross Referenced Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC