Detail Specifications
Thread Class:
2a single mounting facility
Thread Length:
0.417 inches single mounting facility and 0.457 inches single mounting facility
Thread Length:
0.417 inches and 0.457 inches single mounting facility
Hazardous Locations/environmental Protection:
Explosion proof
Overall Length:
Between 2.489 inches and 2.693 inches
First Flat Length:
0.230 inches single actuator and 0.270 inches single actuator
First Flat Length:
0.230 inches and 0.270 inches single actuator
Flat Height:
0.215 inches single actuator and 0.221 inches single actuator
Flat Height:
0.215 inches and 0.221 inches single actuator
Shaft Diameter:
0.248 inches single actuator and 0.251 inches single actuator
Shaft Diameter:
0.248 inches and 0.251 inches single actuator
Shaft Length:
0.834 inches single actuator and 0.914 inches single actuator
Shaft Length:
0.834 inches and 0.914 inches single actuator
Overall Diameter:
Between 1.100 inches and 1.306 inches
Nonturn Device Radius:
0.360 inches at 9: 00 o'clock and 0.390 inches at 9: 00 o'clock
Nonturn Device Radius:
0.360 inches and 0.390 inches at 9: 00 o'clock
Individual Section Quantity:
3
Nonturn Device Type:
Tab at 9: 00 o'clock
Operating Tempurature Range:
-65.0/+125.0 degrees celsius
Switch Contact Basic Design:
Nonpile-up symmetrical
Pole Quantity:
1 each section front
Throw Quantity:
6 each section rear
Mounting Method:
Threaded bushing single mounting facility
Thread Size:
0.375 inches single mounting facility
Contact Voltage Rating In Volts:
115.0 ac at sea level
Contact Voltage Rating In Volts:
28.0 dc at sea level
Shaft Flat/slot Angular Location:
75.0 degrees from nonturn device single actuator
Rotor Through Connection Quantity:
1 each section
Switch Actuator Indexing Position Quantity:
6 single actuator
Shaft Type:
Round, flatted single actuator
Terminal Type:
Tab, solder lug
Contact Switching Action:
Breaks before makes each section rear
Switch Actuator Positioning Increment:
30.0 degrees single actuator
Detent Rotational Torque Range:
+0.500/+2.500 inch-pounds single actuator
Switch Actuator Stop Device Type:
Fixed stop single actuator
Contact Load Current Rating:
2.0 amperes resistive load ac at sea level and 1.0 amperes inductive load ac at sea level
Contact Load Current Rating:
1.0 amperes inductive load dc at sea level
Contact Load Current Rating:
2.0 amperes resistive load and 1.0 amperes inductive load ac at sea level
Style Designator:
Tap, circular, bushing mount
Test Data Document:
81349-mil-s-3786 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Thread Series Designator:
Unef single mounting facility
Item Name:
Voltage Selector
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS