Product Features
Sect. 3 front has 1 dummy terminal
Detail Specifications
Thread Class:
2a 1st mounting facility
Thread Class:
2a 2nd mounting facility
Thread Length:
0.250 inches 1st mounting facility
Thread Length:
0.125 inches 2nd mounting facility
Overall Length:
12.053 inches
Overall Height:
1.312 inches
Overall Width:
1.250 inches
First Flat Length:
0.594 inches single actuator
Flat Height:
0.218 inches single actuator
Shaft Diameter:
0.250 inches single actuator
Shaft Length:
0.594 inches single actuator
Nonturn Device Radius:
0.531 inches at 3: 00 o'clock
Individual Section Quantity:
9
Nonturn Device Type:
Tab at 3: 00 o'clock
Longest Horizontal Distance Between Mounting Centers:
1.031 inches 2nd mounting facility
Operating Tempurature Range:
-25.0/+85.0 degrees celsius
Switch Contact Basic Design:
Nonpile-up symmetrical
Pole Quantity:
1 1st section front
Pole Quantity:
1 2nd section front
Pole Quantity:
1 7th section rear
Pole Quantity:
1 8th section front
Pole Quantity:
1 9th section rear
Pole Quantity:
1 3rd section rear
Pole Quantity:
1 4th section front
Pole Quantity:
1 5th section front
Pole Quantity:
1 5th section rear
Pole Quantity:
1 6th section rear
Pole Quantity:
1 7th section front
Throw Quantity:
1 4th section rear
Throw Quantity:
1 5th section rear
Throw Quantity:
1 2nd section rear
Throw Quantity:
1 3rd section front
Throw Quantity:
2 6th section rear
Throw Quantity:
2 7th section rear
Throw Quantity:
2 8th section front
Throw Quantity:
3 6th section front
Throw Quantity:
3 7th section front
Throw Quantity:
3 8th section rear
Throw Quantity:
3 9th section rear
Throw Quantity:
6 1st section front
Throw Quantity:
6 2nd section front
Throw Quantity:
6 3rd section rear
Throw Quantity:
6 4th section front
Throw Quantity:
6 5th section front
Throw Quantity:
6 9th section front
Mounting Method:
Threaded bushing 1st mounting facility
Mounting Method:
Threaded stud 2nd mounting facility
Thready Qty Per Inch (tpi):
40 2nd mounting facility
Thread Size:
0.112 inches 2nd mounting facility
Thread Size:
0.375 inches 1st mounting facility
Contact Voltage Rating In Volts:
110.0 ac at sea level
Contact Voltage Rating In Volts:
28.0 dc at sea level
Shaft Flat/slot Angular Location:
15.0 degrees from nonturn device single actuator
Rotor Through Connection Quantity:
1 2nd section
Rotor Through Connection Quantity:
1 4th section
Rotor Through Connection Quantity:
1 8th section
Mounting Facility Pattern:
Two position in-line 2nd mounting facility
Switch Actuator Indexing Position Quantity:
12 single actuator
Shaft Type:
Round, flatted single actuator
Contact Switching Action:
Makes before breaks each section front
Contact Switching Action:
Makes before breaks each section rear
Switch Actuator Positioning Increment:
30.0 degrees single actuator
Contact Load Current Rating:
0.5 amperes resistive load ac at sea level
Contact Load Current Rating:
1.0 amperes resistive load dc at sea level
Precious Material And Location:
Contacts and rotor blade silver
Style Designator:
Circular wafer, bushing mount
Thread Series Designator:
Unc 2nd mounting facility
Thread Series Designator:
Unef 1st mounting facility
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC