Range 0 to 100 inches of mercury absolute; pressure connection 1/4 inch npt; overpressure 100% of span; display 4 1/2 digit with decimal point; digits 0.43 inch high; repeatabili type 0.02% of span; temp operating limits +15 degrees f to +150 degrees f; pressure element inconel x718; wetted parts aisi 300 stainless steel; sensing element solid state photo optic detector, measuring motion of a diaphragm or bourdon tube, depending upon range; pressure media liquid or gas; power consumption 7 watts; compatible with eia rs-232-c interface; mounting bench or panel; weight 7.3 lbs; warm up time less than 5 minutes; may be re-zeroed without accuracy loss
NSN 6135-01-346-0851
NSN 5895-01-191-7633
NSN 6220-01-314-9594
NSN 6320-01-052-1669
NSN 5895-00-313-9098
NSN 5996-01-315-9247
NSN 5975-01-041-5836
NSN 6620-00-202-5122
NSN 6145-01-067-6456
NSN 5855-01-334-6594
NSN 5915-01-505-8202
NSN 6320-00-456-2092