Range 0 to 100 inches of mercury absolute; pressure connection 1/4 inch npt; overpressure 100% of span; display 4 1/2 digit with decimal point; digits 0.43 inch high; repeatabili type 0.02% of span; temp operating limits +15 degrees f to +150 degrees f; pressure element inconel x718; wetted parts aisi 300 stainless steel; sensing element solid state photo optic detector, measuring motion of a diaphragm or bourdon tube, depending upon range; pressure media liquid or gas; power consumption 7 watts; compatible with eia rs-232-c interface; mounting bench or panel; weight 7.3 lbs; warm up time less than 5 minutes; may be re-zeroed without accuracy loss
NSN 5975-00-226-8429
NSN 6145-01-472-4661
NSN 6320-00-194-4252
NSN 6145-01-082-9048
NSN 5930-01-407-1089
NSN 6105-01-645-8011
NSN 5920-01-113-7787
NSN 6150-01-400-4211
NSN 6105-01-080-2662
NSN 5905-01-571-8206
NSN 5835-01-386-4027
NSN 5960-01-279-2589