Deltadyne is a matched assembly, parts may not be purchased separately and are not necessarily interchangable. Non-resettable. Actuation pressure: 24 psid + or - 3 psi. System pressure: 100-120 psi; proof: 250 psi; burst: 400 psi. Temperature range: -65 to +300 degrees f. Fluid: lubricating oi (mil-l-7808, mil-l-23699). Once actuated the button remains in the actuated position until the indicator is inverted and manually depressed. Thermal lockout: a bimetal element is provided which prevents actuation below 125 degrees f, permits actuation above 155 degrees f. Has a red indicator button , extends 3/16" when actuated (annodized and dyed red) top surface of indicator button to be clear.
NSN 6685-01-104-3083
NSN 5975-00-129-6056
NSN 6685-00-208-7724
NSN 6145-00-784-3741
NSN 6645-01-258-5558
NSN 6645-00-711-5381
NSN 5999-00-432-8948
NSN 5975-00-189-7849
NSN 6110-01-227-3055
NSN 5855-00-821-7512
NSN 5960-01-386-2786
NSN 5930-00-594-8671
Last Updated: 06/20/2025