Deltadyne is a matched assembly, parts may not be purchased separately and are not necessarily interchangable. Non-resettable. Actuation pressure: 24 psid + or - 3 psi. System pressure: 100-120 psi; proof: 250 psi; burst: 400 psi. Temperature range: -65 to +300 degrees f. Fluid: lubricating oi (mil-l-7808, mil-l-23699). Once actuated the button remains in the actuated position until the indicator is inverted and manually depressed. Thermal lockout: a bimetal element is provided which prevents actuation below 125 degrees f, permits actuation above 155 degrees f. Has a red indicator button , extends 3/16" when actuated (annodized and dyed red) top surface of indicator button to be clear.
NSN 5835-01-163-4215
NSN 6220-00-266-8222
NSN 5950-01-012-1906
NSN 5950-01-347-0312
NSN 5960-01-129-2509
NSN 5996-00-967-9263
NSN 6110-01-019-0811
NSN 5960-01-518-4440
NSN 6620-01-315-1159
NSN 4140-01-362-8017
NSN 6105-00-836-6009
NSN 5960-01-360-4107
Last Updated: 11/21/2024