Deltadyne is a matched assembly, parts may not be purchased separately and are not necessarily interchangable. Non-resettable. Actuation pressure: 24 psid + or - 3 psi. System pressure: 100-120 psi; proof: 250 psi; burst: 400 psi. Temperature range: -65 to +300 degrees f. Fluid: lubricating oi (mil-l-7808, mil-l-23699). Once actuated the button remains in the actuated position until the indicator is inverted and manually depressed. Thermal lockout: a bimetal element is provided which prevents actuation below 125 degrees f, permits actuation above 155 degrees f. Has a red indicator button , extends 3/16" when actuated (annodized and dyed red) top surface of indicator button to be clear.
NSN 5905-01-415-5116
NSN 5935-01-406-2880
NSN 6650-01-112-0453
NSN 7035-00-300-3208
NSN 5960-01-481-8051
NSN 5935-00-057-1572
NSN 6645-00-200-2324
NSN 5910-00-988-7990
NSN 7035-01-026-1171
NSN 5930-01-525-4891
NSN 6650-01-324-6458
NSN 5905-01-393-2519