Deltadyne is a matched assembly, parts may not be purchased separately and are not necessarily interchangable. Non-resettable. Actuation pressure: 24 psid + or - 3 psi. System pressure: 100-120 psi; proof: 250 psi; burst: 400 psi. Temperature range: -65 to +300 degrees f. Fluid: lubricating oi (mil-l-7808, mil-l-23699). Once actuated the button remains in the actuated position until the indicator is inverted and manually depressed. Thermal lockout: a bimetal element is provided which prevents actuation below 125 degrees f, permits actuation above 155 degrees f. Has a red indicator button , extends 3/16" when actuated (annodized and dyed red) top surface of indicator button to be clear.
NSN 6150-01-327-7394
NSN 5985-00-885-7023
NSN 6240-01-559-3806
NSN 5835-01-317-4840
NSN 5925-01-460-7920
NSN 6130-01-214-4620
NSN 5945-01-007-3773
NSN 6685-00-578-5951
NSN 6650-00-059-6268
NSN 6220-01-286-0562
NSN 6150-01-282-7072
NSN 5925-00-044-3194