Indicator case per ms33639-2; dual indicator with 2 scales pressure and temperature; temp range -50 to 150 degrees c; accuracy temp-pressure +/- 2% full scale; scale illumination per mil-l-25467 red; weight 220 gms max; glass 1/16 thick non reflective coating per mil-c-675; dial lamps ms90451-6832 5 volts, 0.060 amps 4 each; visibility angle 46 degrees min; colors: case black 37038 per fed-std-595; scale markings white 37875 per fed-std-595; scale blackground black 37038 per fed-std-595; pointer white 37875 per fed-std-595; external temp sensor res. Bulb per mil-b-7990; external pressure transmitter tru-66/a per mil-t-38230; indicator meets requirements of para 4 mil-a-6752; dielectric strength 500 v rms at 60 hz; connector mates with ms3126e12-10sy
NSN 5998-00-838-2383
NSN 6240-00-738-1878
NSN 6130-01-106-0185
NSN 6135-00-613-1068
NSN 5965-01-010-1258
NSN 5945-00-208-4123
NSN 6620-00-988-0976
NSN 6110-00-500-4914
NSN 6650-01-630-3410
NSN 5985-00-349-9327
NSN 5950-01-200-7561
NSN 5930-01-246-4331
Last Updated: 06/19/2025