Product Features
7 functions
Product Technical Spec.
Overall Length:
3.750 inches
Body Length:
3.000 inches
Body Height:
2.000 inches
Unthreaded Mounting Hole Diameter:
0.169 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
3.375 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
1.000 inches
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
Source Impedance Rating Per Function:
50.0 ohms 5th radio interference
Source Impedance Rating Per Function:
50.0 ohms 6th radio interference
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 1st radio interference
Load Impedance Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 2nd radio interference
Load Impedance Per Function:
50.0 ohms 6th radio interference
Load Impedance Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 5th radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 4th radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 5th radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 6th radio interference
Operating Current Rating Per Function In Amps:
0.0002 1st radio interference0.0002 2nd radio interference0.0002 3rd radio interference0.0002 4th radio interference0.0002 5th radio interference0.0002 6th radio interference
Mounting Facility Type And Quantity:
4 unthreaded hole
Functional Terminal Type And Quantity:
2 connector, receptacle input 1st function7 pin output 2nd function1 pin ground 3rd function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 1st radio interference 1st function115.0 volts ac 2nd radio interference 2nd function115.0 volts ac 3rd radio interference 3rd function115.0 volts ac 4th radio interference 4th function115.0 volts ac 5th radio interference 5th function115.0 volts ac 6th radio interference 6th function
Body Surface Treatment:
Tin
Style Designator:
Rectangular terminal/terminals on opposite surfaces
Cross Referenced Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC