This valve meets requirements of lockheed specification control drwg 3h90032-103 & design specification d3h90032; pressures: operating 3000 psi, proof 4500 psi, burst 7500 psi; ambient temp range -65 to +275 degrees feh; operating fluid mil-h-5606; operating time 1.0 seconds max; voltage range 17 to 30 vdc; major component p/n's: body c5623-11, seat assembly c5624-12, plunger c5623-22, coil assembly c5623-23, ball ms134378
A manually or power operated valve having three or more ports. The direction of the flow through the various ports is controlled by either one or more reciprocating slide(s) or spool(s) with recess areas which mate with ports in an integral or replaceable ported sleeve, or one or more poppet(s). It is designed to change the direction of fluid flow from one valve port to another. An off (no flow) position is not a flow pattern. The valve is designed to actuate various components of a fluid system. A power operated valve may have a manual override. For items which stop, start, or change the flow of fluid, see: valve, solenoid. Excludes valve, plug. See also servovalve, hydraulic; body section, working, linear directional control valve; and valve assembly.
Classification: Other taps, cocks, valves, etc., nesoi
NSN 6620-00-692-4504
NSN 5996-00-644-4662
NSN 6650-01-114-9514
NSN 5855-00-962-5792
NSN 6610-01-055-4147
NSN 5905-01-089-6509
NSN 5935-00-242-8138
NSN 6135-01-657-0554
NSN 6240-01-320-1308
NSN 7035-00-153-3826
NSN 5975-01-192-8694
NSN 6110-01-202-8807