This valve meets requirements of lockheed specification control drwg 3h90032-103 & design specification d3h90032; pressures: operating 3000 psi, proof 4500 psi, burst 7500 psi; ambient temp range -65 to +275 degrees feh; operating fluid mil-h-5606; operating time 1.0 seconds max; voltage range 17 to 30 vdc; major component p/n's: body c5623-11, seat assembly c5624-12, plunger c5623-22, coil assembly c5623-23, ball ms134378
A manually or power operated valve having three or more ports. The direction of the flow through the various ports is controlled by either one or more reciprocating slide(s) or spool(s) with recess areas which mate with ports in an integral or replaceable ported sleeve, or one or more poppet(s). It is designed to change the direction of fluid flow from one valve port to another. An off (no flow) position is not a flow pattern. The valve is designed to actuate various components of a fluid system. A power operated valve may have a manual override. For items which stop, start, or change the flow of fluid, see: valve, solenoid. Excludes valve, plug. See also servovalve, hydraulic; body section, working, linear directional control valve; and valve assembly.
Classification: Other taps, cocks, valves, etc., nesoi
NSN 6130-01-517-6490
NSN 6135-01-614-5335
NSN 5930-01-599-4514
NSN 6650-01-252-8190
NSN 5910-00-467-9302
NSN 6130-01-029-6112
NSN 5990-00-481-5614
NSN 5935-01-267-3127
NSN 5920-01-496-8385
NSN 6145-01-408-5332
NSN 5998-01-216-4880
NSN 6110-01-400-4207