1.0 pct failure rate; 9 wire leads; test data document a81349-mil-r-28776; 1 amp at 28 vdc; lamp 100 ma at 28 vdc; supply voltage 26.5 vdc; coil 1.56 kilohms resistance; coil transient suppression 1 volt max; control signal current 15 ma max; turn-on voltage 0.3 vdc max; base turn-on current 0.13 ma max; turn-off time 7.5 ms max; turn-on time 2 ms max; 0.370 in. Max dia; 0.280 in. Max h
1.780 inches overall length, 1.062 inches single mounting facility center to center distance between mounting facilities parallel to length
1.780 inches overall length, 1.062 inches single mounting facility center to center distance between mounting facilities parallel to length
Riveted on mounting configuration
2b single mounting facility thread class, 1.680 inches overall length, 1.680 inches overall height, 1.000 inches overall width
Steel case material, nickel case surface treated, explosion proof environmental protection, intermittent duty type, 30.0 dc voltage rating in volts
2a single mounting facility thread class, 4.250 inches overall length, 2.625 inches single mounting facility center to center distance between mounting facilities parallel to length
NSN 6320-01-465-2028
NSN 2925-00-953-2920
NSN 6645-01-291-8352
NSN 5925-01-511-5852
NSN 5960-01-495-0859
NSN 6150-01-248-2133
NSN 6650-01-499-5673
NSN 6620-01-067-8336
NSN 5998-01-602-4723
NSN 5915-01-626-3674
NSN 6645-01-031-6402
NSN 5945-00-900-3209
Last Updated: 05/21/2024