1.0 pct failure rate; 9 wire leads; test data document a81349-mil-r-28776; 1 amp at 28 vdc; lamp 100 ma at 28 vdc; supply voltage 26.5 vdc; coil 1.56 kilohms resistance; coil transient suppression 1 volt max; control signal current 15 ma max; turn-on voltage 0.3 vdc max; base turn-on current 0.13 ma max; turn-off time 7.5 ms max; turn-on time 2 ms max; 0.370 in. Max dia; 0.280 in. Max h
1.780 inches overall length, 1.062 inches single mounting facility center to center distance between mounting facilities parallel to length
1.780 inches overall length, 1.062 inches single mounting facility center to center distance between mounting facilities parallel to length
Riveted on mounting configuration
2b single mounting facility thread class, 1.680 inches overall length, 1.680 inches overall height, 1.000 inches overall width
Steel case material, nickel case surface treated, explosion proof environmental protection, intermittent duty type, 30.0 dc voltage rating in volts
2a single mounting facility thread class, 4.250 inches overall length, 2.625 inches single mounting facility center to center distance between mounting facilities parallel to length
NSN 4140-00-381-4563
NSN 6220-01-198-7217
NSN 5990-01-411-7706
NSN 5895-01-116-3271
NSN 5930-01-206-4390
NSN 5960-00-152-9488
NSN 6110-00-897-4594
NSN 6685-00-051-8850
NSN 5950-00-794-9054
NSN 6110-00-525-3418
NSN 6610-00-465-7461
NSN 5999-00-822-9497
Last Updated: 12/18/2024