Used to control gas flow; 2.375 in. O/a lg; 2.750 in. W; 3.250 in. H; metal frame, shaft and springs; nylon gears; 120 vac, 50/60 hz motor w/two 22/20 stranded wire leads 7 in. Lg; 120 vac, 50/60 hz solenoid, two 0.187 in. Quick diconnect terminals; 125-250 vac, 20 amp spdt switch w/three 0.250 in. Quick disconnect terminals; timing cycle 2.4 sec min.- 60 sec max.; ambient temp range 20/160 degrees f; panel mtd w/3 6-32 thd holes set 120 degrees apart, centered in a 0.687 in.Radius, 1 hole at 6 oclock position centered on shaft; momentary operation of switch s1 causes clutch to operate, transfering s2 to n.C.Position and energizing timing motor and load; switch s2 holds the clutch operated until the time cycle is completed and the timing motor transfers s2 to n.O.Position, releasing the clutch and deenergizing the timing motor and load; fragility factor-moderately delicate
NSN 6130-01-227-5005
NSN 5855-01-417-5571
NSN 5960-01-372-5609
NSN 5895-00-164-2726
NSN 6240-01-323-9308
NSN 5960-01-315-6993
NSN 5960-00-153-7115
NSN 7035-01-467-4539
NSN 5895-00-379-4699
NSN 5965-01-496-4765
NSN 6685-00-032-7311
NSN 5920-00-031-5181
Last Updated: 02/03/2025